Calimus wrote:
>
> OK, I know there has been some commenting about all this already, so if
> everyone wants to keep this off list, just e-mail me directly.
>
> I just converted my A/C over to r-134 and basicly is't cooler then the
> outside air, but it's nothing to write home about. I don't have a
> digital thermometer or anything to check whats coming out of the vents,
> but let's just say it's not enough for Ga heat. Now I only put 2 can's
> of coolent in the system and there are no leaks. Would another half a
> can or a whole 3rd can help make a difference?
>
> William
To add some more date points to the survey:
- Did you empty the system 1st?
- Did you pull a vacuum on the system 1st?
- Did you replace the drier?
- Was the system open to the atmosphere prior to being put back into
service?
- Was the system deactivating itself (because of too low pressure) or
was it working but warmly?
TBerk