Unplug one of the wires, plug it into a spare spark plug, lay the plug on the head such that the outer grounded portion makes contact. This way you can ensure a small gap, which prevents possible overvoltage breakdown of the other ignition components. As for checking solo while under hood, have ignition on while jumpering starter solenoid to +12V. HTH Al